A “Reusing a Nonce, Key Pair in Encryption” issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.
Vendor | Product | Version | CPE |
---|---|---|---|
rockwellautomation | 1763-l16awa_series_a | * | cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16awa_series_b | * | cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16bbb_series_a | * | cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16bbb_series_b | * | cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16bwa_series_a | * | cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16bwa_series_b | * | cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16dwd_series_a | * | cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:* |
rockwellautomation | 1763-l16dwd_series_b | * | cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:* |
rockwellautomation | ab_micrologix_controller | 1100 | cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:* |
rockwellautomation | 1766-l32awa_series_a | * | cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:* |
[
{
"product": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"
}
]
}
]
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:N/AC:L/Au:N/C:P/I:N/A:N
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
34.8%