Lucene search

K
cveIcscertCVE-2021-43935
HistoryDec 15, 2021 - 7:15 p.m.

CVE-2021-43935

2021-12-1519:15:15
CWE-287
CWE-288
icscert
web.nvd.nist.gov
41
cve-2021-43935
sso
authentication
vulnerability
ad
access
privileges

CVSS2

6.8

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

CVSS3

9.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

AI Score

9.3

Confidence

High

EPSS

0.002

Percentile

59.4%

The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges.

Affected configurations

Nvd
Node
baxterwelch_allyn_connex_cardioRange1.0.01.1.1
OR
baxterwelch_allyn_diagnostic_cardiology_suiteMatch2.1.0
OR
baxterwelch_allyn_rscribe_resting_ecg_systemRange5.017.0.0
OR
baxterwelch_allyn_vision_express_holter_analysis_systemRange6.1.06.4.0
Node
baxterwelch_allyn_hscribe_holter_analysis_system_firmwareRange5.016.4.0
AND
baxterwelch_allyn_hscribe_holter_analysis_systemMatch-
Node
baxterwelch_allyn_q-stress_cardiac_stress_testing_system_firmwareRange6.0.06.3.1
AND
baxterwelch_allyn_q-stress_cardiac_stress_testing_systemMatch-
Node
baxterwelch_allyn_xscribe_cardiac_stress_testing_system_firmwareRange5.016.3.1
AND
baxterwelch_allyn_xscribe_cardiac_stress_testing_systemMatch-
VendorProductVersionCPE
baxterwelch_allyn_connex_cardio*cpe:2.3:a:baxter:welch_allyn_connex_cardio:*:*:*:*:*:*:*:*
baxterwelch_allyn_diagnostic_cardiology_suite2.1.0cpe:2.3:a:baxter:welch_allyn_diagnostic_cardiology_suite:2.1.0:*:*:*:*:*:*:*
baxterwelch_allyn_rscribe_resting_ecg_system*cpe:2.3:a:baxter:welch_allyn_rscribe_resting_ecg_system:*:*:*:*:*:*:*:*
baxterwelch_allyn_vision_express_holter_analysis_system*cpe:2.3:a:baxter:welch_allyn_vision_express_holter_analysis_system:*:*:*:*:*:*:*:*
baxterwelch_allyn_hscribe_holter_analysis_system_firmware*cpe:2.3:o:baxter:welch_allyn_hscribe_holter_analysis_system_firmware:*:*:*:*:*:*:*:*
baxterwelch_allyn_hscribe_holter_analysis_system-cpe:2.3:h:baxter:welch_allyn_hscribe_holter_analysis_system:-:*:*:*:*:*:*:*
baxterwelch_allyn_q-stress_cardiac_stress_testing_system_firmware*cpe:2.3:o:baxter:welch_allyn_q-stress_cardiac_stress_testing_system_firmware:*:*:*:*:*:*:*:*
baxterwelch_allyn_q-stress_cardiac_stress_testing_system-cpe:2.3:h:baxter:welch_allyn_q-stress_cardiac_stress_testing_system:-:*:*:*:*:*:*:*
baxterwelch_allyn_xscribe_cardiac_stress_testing_system_firmware*cpe:2.3:o:baxter:welch_allyn_xscribe_cardiac_stress_testing_system_firmware:*:*:*:*:*:*:*:*
baxterwelch_allyn_xscribe_cardiac_stress_testing_system-cpe:2.3:h:baxter:welch_allyn_xscribe_cardiac_stress_testing_system:-:*:*:*:*:*:*:*

CNA Affected

[
  {
    "product": "Welch Allyn Q-Stress Cardiac Stress Testing System",
    "vendor": "Hillrom",
    "versions": [
      {
        "lessThanOrEqual": "6.3.1",
        "status": "affected",
        "version": "6.0.0",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Welch Allyn X-Scribe Cardiac Stress Testing System",
    "vendor": "Hillrom",
    "versions": [
      {
        "lessThanOrEqual": "6.3.1",
        "status": "affected",
        "version": "5.01",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Welch Allyn Diagnostic Cardiology Suite",
    "vendor": "Hillrom",
    "versions": [
      {
        "status": "affected",
        "version": "2.1.0"
      }
    ]
  },
  {
    "product": "Welch Allyn Vision Express",
    "vendor": "Hillrom",
    "versions": [
      {
        "lessThanOrEqual": "6.4.0",
        "status": "affected",
        "version": "6.1.0",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Welch Allyn H-Scribe Holter Analysis System",
    "vendor": "Hillrom",
    "versions": [
      {
        "lessThanOrEqual": "6.4.0",
        "status": "affected",
        "version": "5.01",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Welch Allyn R-Scribe Resting ECG System",
    "vendor": "Hillrom",
    "versions": [
      {
        "lessThanOrEqual": "7.0.0",
        "status": "affected",
        "version": "5.01",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Welch Allyn Connex Cardio",
    "vendor": "Hillrom",
    "versions": [
      {
        "lessThanOrEqual": "1.1.1",
        "status": "affected",
        "version": "1.0.0",
        "versionType": "custom"
      }
    ]
  }
]

CVSS2

6.8

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

CVSS3

9.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

AI Score

9.3

Confidence

High

EPSS

0.002

Percentile

59.4%

Related for CVE-2021-43935