Lucene search

K
cveCERTVDECVE-2022-22515
HistoryApr 07, 2022 - 7:15 p.m.

CVE-2022-22515

2022-04-0719:15:08
CWE-668
CERTVDE
web.nvd.nist.gov
64
cve-2022-22515
remote attack
authenticated
configuration file
modify
nvd

CVSS2

4.9

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

SINGLE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:S/C:P/I:P/A:N

CVSS3

8.1

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

AI Score

8.2

Confidence

High

EPSS

0.001

Percentile

50.1%

A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.

Affected configurations

Nvd
Node
codesyscontrol_for_beaglebone_slRange<4.5.0.0
OR
codesyscontrol_for_beckhoff_cx9020Range<4.5.0.0
OR
codesyscontrol_for_empc-a\/imx6_slRange<4.5.0.0
OR
codesyscontrol_for_iot2000_slRange<4.5.0.0
OR
codesyscontrol_for_linux_slRange<4.5.0.0
OR
codesyscontrol_for_pfc100_slRange<4.5.0.0
OR
codesyscontrol_for_pfc200_slRange<4.5.0.0
OR
codesyscontrol_for_plcnext_slRange<4.5.0.0
OR
codesyscontrol_for_raspberry_pi_slRange<4.5.0.0
OR
codesyscontrol_for_wago_touch_panels_600_slRange<4.5.0.0
OR
codesyscontrol_rte_slRange<3.5.18.0
OR
codesyscontrol_rte_sl_\(for_beckhoff_cx\)Range<3.5.18.0
OR
codesyscontrol_runtime_system_toolkitRange<3.5.18.0
OR
codesyscontrol_win_slRange<3.5.18.0
OR
codesysdevelopment_systemRange3.03.5.18.0
OR
codesysembedded_target_visu_toolkitRange<3.5.18.0
OR
codesyshmi_slRange<3.5.18.0
OR
codesysremote_target_visu_toolkitRange<3.5.18.0
VendorProductVersionCPE
codesyscontrol_for_beaglebone_sl*cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_beckhoff_cx9020*cpe:2.3:a:codesys:control_for_beckhoff_cx9020:*:*:*:*:*:*:*:*
codesyscontrol_for_empc-a\/imx6_sl*cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_iot2000_sl*cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_linux_sl*cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_pfc100_sl*cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_pfc200_sl*cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_plcnext_sl*cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_raspberry_pi_sl*cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*
codesyscontrol_for_wago_touch_panels_600_sl*cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*
Rows per page:
1-10 of 181

CNA Affected

[
  {
    "product": "CODESYS Control RTE (SL)",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control RTE (for Beckhoff CX) SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control Win (SL)",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS HMI (SL)",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Development System V3",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control Runtime System Toolkit",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Embedded Target Visu Toolkit",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Remote Target Visu Toolkit",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V3.5.17.40",
        "status": "affected",
        "version": "V3",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for BeagleBone SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for Beckhoff CX9020 SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for emPC-A/iMX6 SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for IOT2000 SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for Linux SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for PFC100 SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for PFC200 SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for PLCnext SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for Raspberry Pi SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "CODESYS Control for WAGO Touch Panels 600 SL",
    "vendor": "CODESYS",
    "versions": [
      {
        "lessThan": "V4.5.0.0",
        "status": "affected",
        "version": "V4",
        "versionType": "custom"
      }
    ]
  }
]

CVSS2

4.9

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

SINGLE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:S/C:P/I:P/A:N

CVSS3

8.1

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

AI Score

8.2

Confidence

High

EPSS

0.001

Percentile

50.1%

Related for CVE-2022-22515