Lucene search

K
cveSiemensCVE-2022-28328
HistoryApr 12, 2022 - 9:15 a.m.

CVE-2022-28328

2022-04-1209:15:15
CWE-20
siemens
web.nvd.nist.gov
56
scalance
w1788
vulnerability
dos
security
nvd

CVSS2

7.8

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

AI Score

7.2

Confidence

High

EPSS

0.001

Percentile

38.4%

A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition.

Affected configurations

Nvd
Node
siemensscalance_w1788-2ia_m12_firmwareRange<3.0.0
AND
siemensscalance_w1788-2ia_m12Match-
Node
siemensscalance_w1788-2_m12_firmwareRange<3.0.0
AND
siemensscalance_w1788-2_m12Match-
Node
siemensscalance_w1788-2_eec_m12_firmwareRange<3.0.0
AND
siemensscalance_w1788-2_eec_m12Match-
Node
siemensscalance_w1788-1_m12_firmwareRange<3.0.0
AND
siemensscalance_w1788-1_m12Match-
VendorProductVersionCPE
siemensscalance_w1788-2ia_m12_firmware*cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:*:*:*:*:*:*:*:*
siemensscalance_w1788-2ia_m12-cpe:2.3:h:siemens:scalance_w1788-2ia_m12:-:*:*:*:*:*:*:*
siemensscalance_w1788-2_m12_firmware*cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:*:*:*:*:*:*:*:*
siemensscalance_w1788-2_m12-cpe:2.3:h:siemens:scalance_w1788-2_m12:-:*:*:*:*:*:*:*
siemensscalance_w1788-2_eec_m12_firmware*cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:*:*:*:*:*:*:*:*
siemensscalance_w1788-2_eec_m12-cpe:2.3:h:siemens:scalance_w1788-2_eec_m12:-:*:*:*:*:*:*:*
siemensscalance_w1788-1_m12_firmware*cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:*:*:*:*:*:*:*:*
siemensscalance_w1788-1_m12-cpe:2.3:h:siemens:scalance_w1788-1_m12:-:*:*:*:*:*:*:*

CNA Affected

[
  {
    "product": "SCALANCE W1788-1 M12",
    "vendor": "Siemens",
    "versions": [
      {
        "status": "affected",
        "version": "All versions < V3.0.0"
      }
    ]
  },
  {
    "product": "SCALANCE W1788-2 EEC M12",
    "vendor": "Siemens",
    "versions": [
      {
        "status": "affected",
        "version": "All versions < V3.0.0"
      }
    ]
  },
  {
    "product": "SCALANCE W1788-2 M12",
    "vendor": "Siemens",
    "versions": [
      {
        "status": "affected",
        "version": "All versions < V3.0.0"
      }
    ]
  },
  {
    "product": "SCALANCE W1788-2IA M12",
    "vendor": "Siemens",
    "versions": [
      {
        "status": "affected",
        "version": "All versions < V3.0.0"
      }
    ]
  }
]

CVSS2

7.8

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

AI Score

7.2

Confidence

High

EPSS

0.001

Percentile

38.4%

Related for CVE-2022-28328