Lucene search

K
cve[email protected]CVE-2023-31408
HistoryMay 15, 2023 - 11:15 a.m.

CVE-2023-31408

2023-05-1511:15:09
CWE-312
web.nvd.nist.gov
16
cve-2023-31408
cleartext storage
sensitive information
sick ftmg
air flow sensor
partnumbers
remote attacker
user credentials
cross-site scripting

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

7.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

49.6%

Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with
Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote
attacker to potentially steal user credentials that are stored in the user’s browsers local storage via
cross-site-scripting attacks.

Affected configurations

NVD
Node
sickftmg-esd20axx_firmwareRange<2.0
AND
sickftmg-esd20axxMatch-
Node
sickftmg-esd25axx_firmwareRange<2.0
AND
sickftmg-esd25axxMatch-
Node
sickftmg-esn40sxx_firmwareRange<2.0
AND
sickftmg-esn40sxxMatch-
Node
sickftmg-esn50sxx_firmwareRange<2.0
AND
sickftmg-esn50sxxMatch-
Node
sickftmg-esr50sxx_firmwareRange<2.0
AND
sickftmg-esr50sxxMatch-
Node
sickftmg-esr40sxx_firmwareRange<2.0
AND
sickftmg-esr40sxxMatch-
Node
sickftmg-esd15axx_firmwareRange<2.0
AND
sickftmg-esd15axxMatch-

CNA Affected

[
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESD15AXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  },
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESD20AXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  },
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESD25AXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  },
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESN40SXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  },
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESN50SXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  },
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESR40SXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  },
  {
    "defaultStatus": "affected",
    "product": "SICK FTMG-ESR50SXX AIR FLOW SENSOR",
    "vendor": "SICK AG",
    "versions": [
      {
        "status": "affected",
        "version": "all firmware versions"
      }
    ]
  }
]

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

7.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

49.6%

Related for CVE-2023-31408