Lucene search

K
cve[email protected]CVE-2023-3573
HistoryAug 08, 2023 - 7:15 a.m.

CVE-2023-3573

2023-08-0807:15:10
CWE-78
web.nvd.nist.gov
20
phoenix contact
wp 6xxx
web panels
command injection
http post
device access
cve-2023-3573
security vulnerability

8.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

8.9 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

35.5%

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges may use a command injection in a HTTP POST request releated to font configuration operationsΒ to gain full access to the device.

Affected configurations

NVD
Node
phoenixcontactwp_6070-wvps_firmwareRange<4.0.10
AND
phoenixcontactwp_6070-wvpsMatch-
Node
phoenixcontactwp_6101-wxps_firmwareRange<4.0.10
AND
phoenixcontactwp_6101-wxpsMatch-
Node
phoenixcontactwp_6121-wxps_firmwareRange<4.0.10
AND
phoenixcontactwp_6121-wxpsMatch-
Node
phoenixcontactwp_6156-whps_firmwareRange<4.0.10
AND
phoenixcontactwp_6156-whpsMatch-
Node
phoenixcontactwp_6185-whps_firmwareRange<4.0.10
AND
phoenixcontactwp_6185-whpsMatch-
Node
phoenixcontactwp_6215-whps_firmwareRange<4.0.10
AND
phoenixcontactwp_6215-whpsMatch-

CNA Affected

[
  {
    "defaultStatus": "unaffected",
    "product": "WP 6070-WVPS",
    "vendor": "PHOENIX CONTACT",
    "versions": [
      {
        "lessThan": "4.0.10",
        "status": "affected",
        "version": "0",
        "versionType": "semver"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "WP 6101-WXPS",
    "vendor": "PHOENIX CONTACT",
    "versions": [
      {
        "lessThan": "4.0.10",
        "status": "affected",
        "version": "0",
        "versionType": "semver"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "WP 6121-WXPS",
    "vendor": "PHOENIX CONTACT",
    "versions": [
      {
        "lessThan": "4.0.10",
        "status": "affected",
        "version": "0",
        "versionType": "semver"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "WP 6156-WHPS",
    "vendor": "PHOENIX CONTACT",
    "versions": [
      {
        "lessThan": "4.0.10",
        "status": "affected",
        "version": "0",
        "versionType": "semver"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "WP 6185-WHPS",
    "vendor": "PHOENIX CONTACT",
    "versions": [
      {
        "lessThan": "4.0.10",
        "status": "affected",
        "version": "0",
        "versionType": "semver"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "WP 6215-WHPS",
    "vendor": "PHOENIX CONTACT",
    "versions": [
      {
        "lessThan": "4.0.10",
        "status": "affected",
        "version": "0",
        "versionType": "semver"
      }
    ]
  }
]

8.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

8.9 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

35.5%

Related for CVE-2023-3573