7.8 High
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.7 High
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
21.5%
Multiple components of Iconics SCADA Suite are prone to a Phantom DLL loading vulnerability. This issue arises from the applications improperly searching for and loading dynamic link libraries, potentially allowing an attacker to execute malicious code via a DLL with a matching name in an accessible search path. The affected components are:
MMXFax.exe * winfax.dll
MelSim2ComProc.exe
Sim2ComProc.dll
MMXCall_in.exe * libdxxmt.dll
libsrlmt.dll
CPE | Name | Operator | Version |
---|---|---|---|
iconics:iconics_suite | iconics iconics suite | lt | 10.97.2 |
[
{
"defaultStatus": "unknown",
"platforms": [
"Windows"
],
"product": "SCADA software Iconics Suite",
"vendor": "ICONICS",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "10.97.2",
"versionType": "semver"
}
]
}
]
7.8 High
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.7 High
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
21.5%