Lucene search

K
cve[email protected]CVE-2024-1915
HistoryMar 15, 2024 - 1:15 a.m.

CVE-2024-1915

2024-03-1501:15:58
CWE-468
web.nvd.nist.gov
37
mitsubishi electric
melsec-q
melsec-l
cpu modules
vulnerability
remote code execution
cve-2024-1915
nvd

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

7.4 High

AI Score

Confidence

Low

0.0004 Low

EPSS

Percentile

15.7%

Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.

CNA Affected

[
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q03UDECPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q04UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q06UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q10UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q13UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q20UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q26UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q50UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q100UDEHCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q03UDVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q04UDVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q06UDVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q13UDVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q26UDVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q04UDPVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q06UDPVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q13UDPVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-Q Series Q26UDPVCPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26061\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L02CPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L06CPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L26CPU",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L02CPU-P",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L06CPU-P",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L26CPU-P",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L26CPU-BT",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MELSEC-L Series L26CPU-PBT",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "The first 5 digits of serial No. \"26041\" and prior"
      }
    ]
  }
]

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

7.4 High

AI Score

Confidence

Low

0.0004 Low

EPSS

Percentile

15.7%

Related for CVE-2024-1915