Lucene search

K
cvelistRapid7CVELIST:CVE-2019-5617
HistoryNov 06, 2019 - 6:30 p.m.

CVE-2019-5617 C4G BLIS Improper Access Control

2019-11-0618:30:42
CWE-284
rapid7
www.cve.org
3

CVSS3

10

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

AI Score

9.7

Confidence

High

EPSS

0.006

Percentile

78.6%

Computing For Good’s Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, “Improper Access Control.” As a result, an unauthenticated user may change the password of any administrator-level user.

CNA Affected

[
  {
    "product": "Basic Laboratory Information System",
    "vendor": "Computing For Good",
    "versions": [
      {
        "lessThanOrEqual": "3.4",
        "status": "affected",
        "version": "unspecified",
        "versionType": "custom"
      }
    ]
  }
]

CVSS3

10

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

AI Score

9.7

Confidence

High

EPSS

0.006

Percentile

78.6%