Lucene search

K
cvelistIDEMIACVELIST:CVE-2023-33218
HistoryDec 15, 2023 - 11:31 a.m.

CVE-2023-33218 Stack Buffer Overflow in a binary run at upgrade startup

2023-12-1511:31:27
CWE-121
IDEMIA
www.cve.org
2
cve-2023-33218
parameter zone read
parameter zone write
remote code execution
targeted device

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N

AI Score

10

Confidence

High

EPSS

0.002

Percentile

59.5%

The Parameter Zone Read and Parameter Zone Write command handlers allow performing a Stack buffer overflow.
This could potentially lead to a Remote Code execution on the targeted device.

CNA Affected

[
  {
    "defaultStatus": "unaffected",
    "product": "SIGMA Lite & Lite +",
    "vendor": "IDEMIA",
    "versions": [
      {
        "lessThan": "4.15.5",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "SIGMA Wide",
    "vendor": "IDEMIA",
    "versions": [
      {
        "lessThan": "4.15.5",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "SIGMA Extreme",
    "vendor": "IDEMIA",
    "versions": [
      {
        "lessThan": "4.15.5",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MorphoWave Compact/XP",
    "vendor": "IDEMIA",
    "versions": [
      {
        "lessThan": "2.12.2",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "VisionPass",
    "vendor": "IDEMIA",
    "versions": [
      {
        "lessThan": "2.12.2",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "MorphoWave SP",
    "vendor": "IDEMIA",
    "versions": [
      {
        "lessThan": "1.2.7",
        "status": "affected",
        "version": "0",
        "versionType": "custom"
      }
    ]
  }
]

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N

AI Score

10

Confidence

High

EPSS

0.002

Percentile

59.5%

Related for CVELIST:CVE-2023-33218