HistorySep 25, 2022 - 11:13 p.m.

Security Bulletin: IBM SPSS SamplePower olch2x32 ActiveX control vulnerability (CVE-2013-0593)

2022-09-2523:13:40
www.ibm.com
7
remote code execution
ibm spss samplepower
activex control
cve-2013-0593
internet explorer
security vulnerability
windows v3.0

EPSS

0.086

Percentile

94.5%

Abstract

There is a security vulnerability with the olch2x32 ActiveX control shipped by IBM SPSS SamplePower Version 3. The vulnerability allows remote attackers to execute arbitrary code on installations of SamplePower when the control is invoked as ActiveX by Microsoft Internet Explorer.

Content

VULNERABILITY DETAILS:

CVE IDs: CVE-2013-0593

DESCRIPTION: It is possible for an attacker to compromise the olch2x32 ActiveX control used within IBM SPSS SamplePower to remotely execute arbitrary code by instantiating this control from Microsoft Internet Explorer. For a remote attacker to exploit these vulnerabilities in SamplePower releases, the following must be accomplished:

1. The user must have IBM SPSS SamplePower installed on the machine.
Important Note: Continuous use of SamplePower is not required; the vulnerabilities may be exploited against the ActiveX control regardless of the use of the product.

2. Attacker needs to create malicious code that would exploit the ActiveX control. This code could be part of an attachment by means of e-mail or a Web page.

3. User must be persuaded to execute the attachment or follow a Web site link that contains the malicious code via the Microsoft Internet Explorer Web browser.

4. If the malicious website is running within Internet Explorer’s Internet Zone, the user must typically authorize the ActiveX pop-up dialog before it could be used.

As of April 24, 2013, IBM has not received any reports of customer issues related to these security vulnerabilities.

These vulnerabilities were reported to IBM by HP’s Zero Day Initiative (ZDI) and discovered by a third-party researcher, rgod, working with ZDI.

CVSS:
Using the Common Vulnerability Scoring System (CVSS) v2, the security ratings for these issues are:

CVSS Base Score: 9.3
CVSS Temporal Score: See <https://exchange.xforce.ibmcloud.com/vulnerabilities/83382&gt; for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (AV:N/AC:M/AU:N/C:C/I:C/A:C)

AFFECTED PLATFORMS:
IBM SPSS SamplePower for Windows V3.0

REMEDIATION:
The recommended solution is to apply the workaround as soon as possible or download and install the IBM SamplePower 3.0 FP1.

Fix* VRMF APAR How to acquire fix
3.0-IM-S3SAMPC-WIN32-FP001 3.0.0.1 N/A Download 3.0-IM-S3SAMPC-WIN32-FP001

Workaround:
Disable the use of the vulnerable ActiveX control within Internet Explorer.

Note: This solution contains information about modifying the Microsoft operating system registry. Before making any modifications with the Microsoft Registry Editor, it is strongly recommended that you make a backup of the existing registry. For more information about how to back up the registry refer to Microsoft Knowledge Base article 256986.

The vulnerable ActiveX control can be disabled in Internet Explorer by manually setting the kill bit. Complete the following steps to set the kill bit on the machine where SamplePower is installed.

1. Start the Microsoft Windows Registry Editor (regedit).

2. Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Internet Explorer\ActiveXCompatibility

3. Add a new Key:
{92D71E93-25A8-11CF-A640-9986B64D9618}

4. Select that Key and create a new DWORD value named:
Compatibility Flags

5. Set the Compatibility Flags value to:
0x00000400

6. Exit the Registry Editor.

7. Restart Internet Explorer.

Mitigation(s):
None known apply the workaround.

REFERENCES:

Note: According to the Forum of Incident Response and Security Teams (FIRST), the Common Vulnerability Scoring System (CVSS) is an β€œindustry open standard designed to convey vulnerability severity and help to determine urgency and priority of response.” IBM PROVIDES THE CVSS SCORES β€œAS IS” WITHOUT WARRANTY OF ANY KIND, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. CUSTOMERS ARE RESPONSIBLE FOR ASSESSING THE IMPACT OF ANY ACTUAL OR POTENTIAL SECURITY VULNERABILITY.

Related Information

Need more help? Our SamplePower forum is Live!

[{β€œProduct”:{β€œcode”:β€œSS6A5A”,β€œlabel”:β€œIBM SPSS SamplePower”},β€œBusiness Unit”:{β€œcode”:β€œBU059”,β€œlabel”:β€œIBM Software w/o TPS”},β€œComponent”:β€œβ€“β€,β€œPlatform”:[{β€œcode”:β€œPF033”,β€œlabel”:β€œWindows”}],β€œVersion”:β€œ3.0”,β€œEdition”:β€œβ€,β€œLine of Business”:{β€œcode”:β€œLOB10”,β€œlabel”:β€œData and AI”}}]

EPSS

0.086

Percentile

94.5%

Related for 34D9B2358405B39AACD3D543F0E7CFB6735A4711267FA145F031BA5FD1145D7D