Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-21-257-09
HistorySep 14, 2021 - 12:00 p.m.

Siemens NX

2021-09-1412:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
29
siemens nx
use after free
out-of-bounds read
arbitrary code execution
access violation
vulnerabilities
versions
critical manufacturing
worldwide
update
industrial security guidelines

CVSS2

6.8

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

CVSS3

7.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

AI Score

8.2

Confidence

High

EPSS

0.002

Percentile

56.4%

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8 *ATTENTION: Low attack complexity
  • **Vendor:**Siemens
  • **Equipment:**NX
  • Vulnerabilities: Use After Free, Out-of-bounds Read

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could lead to an access violation and to arbitrary code execution on the target host system.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of NX are affected:

  • NX 1980 Series: All versions prior to v1984

3.2 VULNERABILITY OVERVIEW

3.2.1 USE AFTER FREE CWE-416

The IFC adapter in the affected application contains a use-after-free vulnerability, which could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2021-37202 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.2 OUT-OF-BOUNDS READ CWE-125

The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files, which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.

CVE-2021-37203 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H).

3.3 BACKGROUND

  • **CRITICAL INFRASTRUCTURE SECTORS:**Critical Manufacturing
  • **COUNTRIES/AREAS DEPLOYED:**Worldwide
  • **COMPANY HEADQUARTERS LOCATION:**Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:

As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens operational guidelines for industrial security and follow the recommendations in the product manuals.

Additional information on industrial security by Siemens can be found at: <https://www.siemens.com/industrialsecurity&gt;

For more information about this issue, please see Siemens Security Advisory SSA-208530

CISA recommends users take the following measures to protect themselves from social engineering attacks:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.

References

CVSS2

6.8

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

CVSS3

7.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

AI Score

8.2

Confidence

High

EPSS

0.002

Percentile

56.4%

Related for ICSA-21-257-09