CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
39.2%
Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process.
Siemens reports these vulnerabilities affect the following Parasolid 3D geometric modeling tools:
ā¢ Parasolid V34.0: versions prior to V34.0.252
ā¢ Parasolid V34.0: versions prior to V34.0.254
ā¢ Parasolid V34.1: versions prior to V34.1.242
ā¢ Parasolid V34.1: versions prior to V34.1.244
ā¢ Parasolid V35.0: versions prior to V35.0.184
ā¢ Parasolid V35.0: versions prior to V35.0.170
Siemens Parasolid contains an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2022-39157 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
Siemens Parasolid contains an out-of-bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2022-43397 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
ā¢ CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
ā¢ COUNTRIES/AREAS DEPLOYED: Worldwide
ā¢ COMPANY HEADQUARTERS LOCATION: Germany
An anonymous researcher working with Trend Micro Zero Day Initiative reported these vulnerabilities to Siemens.
Siemens has released updates for the affected products and recommends updating to the latest versions:
ā¢ Parasolid V34.0: Update to V34.0.252 or later version.
ā¢ Parasolid V34.0: Update to V34.0.254 or later version.
ā¢ Parasolid V34.1: Update to V34.1.242 or later version.
ā¢ Parasolid V34.1: Update to V34.1.244 or later version.
ā¢ Parasolid V35.0: Update to V35.0.184 or later version.
ā¢ Parasolid V35.0: Update to V35.0.170 or later version.
Siemens has identified the following specific workaround and mitigation customers can apply to reduce the risk:
ā¢ Do not open untrusted X_T files in Parasolid.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemensā operational guidelines for industrial security and to follow the recommendations in the product manuals.
Siemens also provides additional information on industrial security on their website. For more information on security vulnerabilities in Siemensā products, users should contact Siemens.
For more information, see the associated Siemens security advisory SSA-853037 in HTML or CSAF formats.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01BāTargeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. These vulnerabilities have a low attack complexity
cert-portal.siemens.com/productcert/csaf/ssa-853037.json
cert-portal.siemens.com/productcert/html/ssa-853037.html
cisa.gov/ics
cisa.gov/ics
cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-01
cwe.mitre.org/data/definitions/125.html
cwe.mitre.org/data/definitions/787.html
nvd.nist.gov/vuln/detail/CVE-2022-39157
nvd.nist.gov/vuln/detail/CVE-2022-43397
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
support.sw.siemens.com/
support.sw.siemens.com/
support.sw.siemens.com/
support.sw.siemens.com/
support.sw.siemens.com/
support.sw.siemens.com/cs-CZ/
twitter.com/CISAgov
twitter.com/intent/tweet?text=Siemens%20Parasolid+https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-01
us-cert.cisa.gov/ics/Recommended-Practices
us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
www.cisa.gov/uscert/ncas/tips/ST04-014
www.cisa.gov/uscert/sites/default/files/publications/emailscams_0905.pdf
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-01&title=Siemens%20Parasolid
www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-01
www.oig.dhs.gov/
www.siemens.com/cert/advisories
www.siemens.com/cert/operational-guidelines-industrial-security
www.siemens.com/industrialsecurity
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Siemens%20Parasolid&body=www.cisa.gov/news-events/ics-advisories/icsa-22-314-01
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
39.2%