Delta DOPSoft <= 2.00.07 Multiple Vulnerabilities

2022-09-0200:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
83

6.8 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

7.8 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

0.876 High

EPSS

Percentile

98.7%

The version of Delta DOPSoft installed on the remote host is prior to or equal to 2.00.07. It is, therefore, affected by multiple vulnerabilities as referenced in the CISA ICSA-21-252-02 advisory.

  • Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process. (CVE-2021-38402)

  • Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (CVE-2021-38404)

  • Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process. (CVE-2021-38406)

Note that Nessus has not tested for these issues but has instead relied only on the application’s self-reported version number.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(164640);
  script_version("1.7");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/03/23");

  script_cve_id("CVE-2021-38402", "CVE-2021-38404", "CVE-2021-38406");
  script_xref(name:"CISA-KNOWN-EXPLOITED", value:"2022/09/15");

  script_name(english:"Delta DOPSoft <= 2.00.07 Multiple Vulnerabilities");

  script_set_attribute(attribute:"synopsis", value:
"Delta DOPSoft installed on the remote host is affected by a privilege escalation vulnerability.");
  script_set_attribute(attribute:"description", value:
"The version of Delta DOPSoft installed on the remote host is prior to or equal to 2.00.07. It is, therefore, affected
by multiple vulnerabilities as referenced in the CISA ICSA-21-252-02 advisory.

  - Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when
    parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a
    buffer during font string handling. An attacker could leverage this vulnerability to execute code in the
    context of the current process. (CVE-2021-38402)

  - Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when
    parsing specific project files. This could result in a heap-based buffer overflow. An attacker could
    leverage this vulnerability to execute code in the context of the current process. (CVE-2021-38404)

  - Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when
    parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker
    could leverage this vulnerability to execute code in the context of the current process. (CVE-2021-38406)

Note that Nessus has not tested for these issues but has instead relied only on the application's self-reported version
number.");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/uscert/ics/advisories/icsa-21-252-02");
  script_set_attribute(attribute:"solution", value:
"DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product.
Delta Electronics recommends users to switch to the replacement software when available.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:H/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:H/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-38406");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");

  script_set_attribute(attribute:"vuln_publication_date", value:"2021/09/17");
  script_set_attribute(attribute:"patch_publication_date", value:"2021/10/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/09/02");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:deltaww:dopsoft");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Windows");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("delta_dopsoft_win_installed.nbin");
  script_require_keys("installed_sw/Delta DOPSoft");

  exit(0);
}

include('vcf.inc');

var app_info = vcf::get_app_info(app:'Delta DOPSoft', win_local:TRUE);

app_info.display_version = app_info.version + " (file version)";

# After installing the package DELTA_IA-HMI_DOPSoft-2-00-07-04_SW_TC-SC-EN-SP_20171214,
# Files are installed to C:\Program Files (x86)\Delta Industrial Automation\DOPSoft 2.00.07\
# and the DOPSoft.exe has a file version of 4.0.7.4 (not 2.x)
# 2.00.07 file version is 4.0.7.4
var constraints = [
  { 'max_version': '4.0.7.4', 'fixed_display':'See ICSA-21-252-02 advisory or contact Delta.' }
];

vcf::check_version_and_report(
  app_info:app_info,
  constraints:constraints,
  severity:SECURITY_WARNING
);
VendorProductVersionCPE
deltawwdopsoftcpe:/a:deltaww:dopsoft

6.8 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

7.8 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

0.876 High

EPSS

Percentile

98.7%