CVSS2
Attack Vector
LOCAL
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
COMPLETE
Integrity Impact
COMPLETE
Availability Impact
COMPLETE
AV:L/AC:L/Au:N/C:C/I:C/A:C
EPSS
Percentile
5.1%
The EMC NetWorker installed on the remote Windows host is a version prior to 8.0.4.3, or version 8.1.x prior to 8.1.2.6, or 8.2.x prior to 8.2.1.2 . It is, therefore, affected by a buffer overflow flaw in the nsr_render_log command-line interface. A local attacker can exploit this to execute arbitrary code with root privileges on all EMC Networker managed hosts.
#
# (C) Tenable Network Security, Inc.
#
include("compat.inc");
if (description)
{
script_id(83032);
script_version("1.7");
script_cvs_date("Date: 2018/11/15 20:50:26");
script_cve_id("CVE-2015-0530");
script_bugtraq_id(74164);
script_name(english:"EMC NetWorker nsr_render_log Local Privilege Escalation");
script_summary(english:"Checks the version of EMC NetWorker.");
script_set_attribute(attribute:"synopsis", value:
"The remote Windows host has an application installed that is affected
by a local privilege escalation vulnerability.");
script_set_attribute(attribute:"description", value:
"The EMC NetWorker installed on the remote Windows host is a version
prior to 8.0.4.3, or version 8.1.x prior to 8.1.2.6, or 8.2.x prior to
8.2.1.2 . It is, therefore, affected by a buffer overflow flaw in the
nsr_render_log command-line interface. A local attacker can exploit
this to execute arbitrary code with root privileges on all EMC
Networker managed hosts.");
script_set_attribute(attribute:"see_also", value:"https://seclists.org/bugtraq/2015/Apr/att-103/ESA-2015-069.txt");
script_set_attribute(attribute:"solution", value:
"Upgrade to EMC NetWorker 8.0.4.3 / 8.1.2.6 / 8.2.1.2 or later.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2015/04/13");
script_set_attribute(attribute:"patch_publication_date", value:"2015/04/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2015/04/23");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/a:emc:networker");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Windows");
script_copyright(english:"This script is Copyright (C) 2015-2018 Tenable Network Security, Inc.");
script_dependencies("emc_networker_installed.nasl");
script_require_keys("installed_sw/EMC NetWorker");
exit(0);
}
include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");
include("install_func.inc");
appname = "EMC NetWorker";
install = get_single_install(app_name:appname, exit_if_unknown_ver:TRUE);
version = install['version'];
path = install['path'];
fix = NULL;
if (ver_compare(ver:version, fix:'8.0.4.3', strict:FALSE) < 0)
fix = '8.0.4.3';
else if (version =~ "^8\.1\." && ver_compare(ver:version, fix:'8.1.2.6', strict:FALSE) < 0)
fix = '8.1.2.6';
else if (version =~ "^8\.2\." && ver_compare(ver:version, fix:'8.2.1.2', strict:FALSE) < 0)
fix = '8.2.1.2';
else
audit(AUDIT_INST_PATH_NOT_VULN, 'EMC NetWorker', version, path);
port = get_kb_item('SMB/transport');
if (!port) port = 445;
if (report_verbosity > 0)
{
report =
'\n Path : ' + path +
'\n Installed version : ' + version +
'\n Fixed version : ' + fix +
'\n';
security_hole(port:port, extra:report);
}
else security_hole(port);