CVSS2
Attack Vector
LOCAL
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:L/AC:L/Au:N/C:P/I:N/A:N
EPSS
Percentile
5.1%
The version of EMC NetWorker (formerly Legato NetWorker) Module for MEDITECH (NMMEDI) installed on the remote host is 3.0 build 87 - 90.
It is, therefore, affected by a local information disclosure vulnerability due to RecoverPoint and Plink commands storing plaintext RecoverPoint Appliance login credentials in NMMEDI log files.
#
# (C) Tenable Network Security, Inc.
#
include("compat.inc");
if (description)
{
script_id(78823);
script_version("1.4");
script_cvs_date("Date: 2018/11/15 20:50:26");
script_cve_id("CVE-2014-4620");
script_bugtraq_id(70726);
script_name(english:"EMC NetWorker Module for MEDITECH 3.0 Build 87 - 90 Local Information Disclosure");
script_summary(english:"Checks the version of EMC NetWorker Module for MEDITECH.");
script_set_attribute(attribute:"synopsis", value:
"The remote Windows host has an application installed that is affected
by a local information disclosure vulnerability.");
script_set_attribute(attribute:"description", value:
"The version of EMC NetWorker (formerly Legato NetWorker) Module for
MEDITECH (NMMEDI) installed on the remote host is 3.0 build 87 - 90.
It is, therefore, affected by a local information disclosure
vulnerability due to RecoverPoint and Plink commands storing plaintext
RecoverPoint Appliance login credentials in NMMEDI log files.");
script_set_attribute(attribute:"see_also", value:"http://support.emc.com/kb/193627");
script_set_attribute(attribute:"see_also", value:"https://seclists.org/bugtraq/2014/Oct/att-144/ESA-2014-087.txt");
script_set_attribute(attribute:"solution", value:
"Upgrade to EMC NetWorker Module for MEDITECH 3.0 build 92 / 8.2 build
479 or later.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:P/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2014/10/24");
script_set_attribute(attribute:"patch_publication_date", value:"2014/10/24");
script_set_attribute(attribute:"plugin_publication_date", value:"2014/11/03");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/a:emc:networker");
script_set_attribute(attribute:"cpe", value:"cpe:/a:meditech:meditech");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Windows");
script_copyright(english:"This script is Copyright (C) 2014-2018 Tenable Network Security, Inc.");
script_dependencies("emc_networker_installed.nasl");
script_require_keys("installed_sw/EMC NetWorker");
exit(0);
}
include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");
include("install_func.inc");
appname = "EMC NetWorker";
modname = 'Module for MEDITECH';
fullname = appname+" "+modname;
install = get_single_install(app_name:appname, exit_if_unknown_ver:TRUE);
version = install[modname+' Version'];
path = install['path'];
# Module is not installed
if (empty_or_null(version)) audit(AUDIT_NOT_INST, fullname);
if (
ver_compare(ver:version,fix:"3.0.0.87", strict:FALSE) >= 0 &&
ver_compare(ver:version,fix:"3.0.0.90", strict:FALSE) <= 0
)
{
port = get_kb_item("SMB/transport");
if (isnull(port)) port = 445;
if (report_verbosity > 0)
{
report =
'\n Path : ' + path +
'\n Installed version : ' + version +
'\n Fixed version : 3.0.0.92 / 8.2.0.1.479' +
'\n';
security_note(port:port, extra:report);
}
else security_note(port);
}
else audit(AUDIT_INST_PATH_NOT_VULN, fullname, version, path);