nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_ABB_CVE-2023-5767.NASL
HistoryDec 18, 2023 - 12:00 a.m.

ABB RTU500 Products Cross-site Scripting (CVE-2023-5767)

2023-12-1800:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
8
cross-site scripting
abb rtu500
webserver
improperly sanitized
rdt language file
tenable.ot

6.1 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

0.0005 Low

EPSS

Percentile

17.1%

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross- site scripting on the webserver due to an RDT language file being improperly sanitized.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501836);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/02/21");

  script_cve_id("CVE-2023-5767");

  script_name(english:"ABB RTU500 Products Cross-site Scripting (CVE-2023-5767)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability exists in the webserver that affects the RTU500 series
product versions listed below. A malicious actor could perform cross-
site scripting on the webserver due to an RDT language file being
improperly sanitized.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?e97b4773");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-5767");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(79);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/12/04");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/12/04");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/12/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:12");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/ABB");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/ABB');

var asset = tenable_ot::assets::get(vendor:'ABB');

var vuln_cpes = {
    "cpe:/o:hitachienergy:rtu520_firmware:12.0" :
        {"versionEndIncluding" : "12.0.14", "versionStartIncluding" : "12.0.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:12.2" :
        {"versionEndIncluding" : "12.2.11", "versionStartIncluding" : "12.2.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:12.4" :
        {"versionEndIncluding" : "12.4.11", "versionStartIncluding" : "12.4.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:12.6" :
        {"versionEndIncluding" : "12.6.9", "versionStartIncluding" : "12.6.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:12.7" :
        {"versionEndIncluding" : "12.7.6", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:13.2" :
        {"versionEndIncluding" : "13.2.6", "versionStartIncluding" : "13.2.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:13.4" :
        {"versionEndIncluding" : "13.4.3", "versionStartIncluding" : "13.4.1", "family" : "AbbRTU500"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
hitachienergyrtu520_firmware12cpe:/o:hitachienergy:rtu520_firmware:12
hitachienergyrtu520_firmware13cpe:/o:hitachienergy:rtu520_firmware:13

6.1 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

0.0005 Low

EPSS

Percentile

17.1%

Related for TENABLE_OT_ABB_CVE-2023-5767.NASL