CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
COMPLETE
AV:N/AC:L/Au:N/C:N/I:N/A:C
AI Score
Confidence
High
EPSS
Percentile
56.2%
A vulnerability in the Internet Key Exchange Version 2 (IKEv2) module of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause a reload of the affected device that would lead to a denial of service (DoS) condition. The vulnerability is due to how an affected device processes certain malformed IKEv2 packets. An attacker could exploit this vulnerability by sending malformed IKEv2 packets to an affected device to be processed. An exploit could allow the attacker to cause a reload of the affected device that would lead to a DoS condition.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501816);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2023/12/15");
script_cve_id("CVE-2014-2108");
script_name(english:"Rockwell Automation Stratix Cisco IOS Software Internet Key Exchange Version 2 Denial of Service (CVE-2014-2108)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability in the Internet Key Exchange Version 2 (IKEv2)
module of Cisco IOS Software and Cisco IOS XE Software could allow
an unauthenticated, remote attacker to cause a reload of the affected
device that would lead to a denial of service (DoS) condition.
The vulnerability is due to how an affected device processes certain
malformed IKEv2 packets. An attacker could exploit this vulnerability
by sending malformed IKEv2 packets to an affected device to be processed.
An exploit could allow the attacker to cause a reload of the affected
device that would lead to a DoS condition.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
# https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20140326-ikev2
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?5e1e905b");
# https://www.rockwellautomation.com/en-us/support/advisory.PN965.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?141f2981");
# https://www.cisa.gov/news-events/ics-advisories/icsa-17-094-04
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c7bf8ef2");
script_set_attribute(attribute:"solution", value:
"Rockwell Automation has provided a new firmware version,
Version 15.6.3, to mitigate these vulnerabilities.
See Rockwell Automation's security advisory for more information.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2014-2108");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(755);
script_set_attribute(attribute:"vuln_publication_date", value:"2014/03/27");
script_set_attribute(attribute:"patch_publication_date", value:"2014/03/27");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/11/15");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/h:rockwellautomation:allen-bradley_stratix_5900_industrial_managed_ethernet_switch");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Rockwell");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Rockwell');
var asset = tenable_ot::assets::get(vendor:'Rockwell');
var vuln_cpes = {
"cpe:/h:rockwellautomation:allen-bradley_stratix_5900_industrial_managed_ethernet_switch" :
{"versionEndExcluding" : "15.6.3", "family" : "Stratix"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);