CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
COMPLETE
AV:N/AC:M/Au:N/C:P/I:P/A:C
CVSS3
Attack Vector
NETWORK
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
78.8%
A vulnerability in the DNS forwarder functionality of Cisco IOS and IOS XE Software could allow an unauthenticated, remote attacker to cause the device to reload, corrupt the information present in the device’s local DNS cache, or read part of the process memory. The vulnerability is due to a flaw in handling crafted DNS response messages. An attacker could exploit this vulnerability by intercepting and crafting a DNS response message to a client DNS query that was forwarded from the affected device to a DNS server. A successful exploit could cause the device to reload, resulting in a denial of service (DoS) condition or corruption of the local DNS cache information.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501822);
script_version("1.1");
script_set_attribute(attribute:"plugin_modification_date", value:"2023/11/16");
script_cve_id("CVE-2016-6380");
script_name(english:"Rockwell Automation Stratix Cisco IOS and IOS XE Software DNS Forwarder Denial of Service (CVE-2016-6380)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability in the DNS forwarder functionality of Cisco IOS and
IOS XE Software could allow an unauthenticated, remote attacker to
cause the device to reload, corrupt the information present in the
device's local DNS cache, or read part of the process memory.
The vulnerability is due to a flaw in handling crafted DNS response messages.
An attacker could exploit this vulnerability by intercepting and crafting
a DNS response message to a client DNS query that was forwarded from the
affected device to a DNS server. A successful exploit could cause the device
to reload, resulting in a denial of service (DoS) condition or corruption of
the local DNS cache information.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
# https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160928-dns
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?37daabf8");
# https://www.rockwellautomation.com/en-us/support/advisory.PN965.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?141f2981");
# https://www.cisa.gov/news-events/ics-advisories/icsa-17-094-04
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c7bf8ef2");
script_set_attribute(attribute:"solution", value:
"Rockwell Automation has provided a new firmware version,
Version 15.6.3, to mitigate these vulnerabilities.
See Rockwell Automation's security advisory for more information.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:P/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-6380");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(755);
script_set_attribute(attribute:"vuln_publication_date", value:"2016/10/05");
script_set_attribute(attribute:"patch_publication_date", value:"2016/10/05");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/11/15");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/h:rockwellautomation:allen-bradley_stratix_5900_industrial_managed_ethernet_switch");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Rockwell");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Rockwell');
var asset = tenable_ot::assets::get(vendor:'Rockwell');
var vuln_cpes = {
"cpe:/h:rockwellautomation:allen-bradley_stratix_5900_industrial_managed_ethernet_switch" :
{"versionEndExcluding" : "15.6.3", "family" : "Stratix"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
COMPLETE
AV:N/AC:M/Au:N/C:P/I:P/A:C
CVSS3
Attack Vector
NETWORK
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
78.8%