CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:N/C:N/I:P/A:N
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
CHANGED
Confidentiality Impact
LOW
Integrity Impact
LOW
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
AI Score
Confidence
High
EPSS
Percentile
73.1%
Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted user’s web browser to gain access to the affected device.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500118);
script_version("1.10");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");
script_cve_id("CVE-2018-19615");
script_xref(name:"ICSA", value:"19-050-04");
script_xref(name:"EDB-ID", value:"45928");
script_name(english:"Rockwell Automation Allen-Bradley PowerMonitor 1000 Improper Neutralization of Input During Web Page Generation (CVE-2018-19615)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a
targeted user's web browser to gain access to the affected device.
This plugin only works with Tenable.ot. Please
visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://www.exploit-db.com/exploits/45928/");
# http://packetstormsecurity.com/files/150600/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-XSS.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?6a44fb68");
script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/106333");
script_set_attribute(attribute:"see_also", value:"https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04");
script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/108538");
# https://www.rockwellautomation.com/en-us/support/advisory.PN1059.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?b70f3206");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Rockwell Automation has released FRN 4.019, which addresses the reported vulnerabilities.
Rockwell Automation reports CheckPoint Software Technologies has released IPS rules to detect attempts to exploit
CVE-2018-19615.
In the event a user can not apply the FRN 4.019 patch, Rockwell Automation notes users can temporarily mitigate these
vulnerabilities by disabling the FTP port using the LCD configuration menu or in the configuration options. Users can
also disable access to the webpage using the LCD screen configuration menu or in the configuration options.
For more information, Rockwell Automation has released a security notification (login required).");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:N/I:P/A:N");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-19615");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(79);
script_set_attribute(attribute:"vuln_publication_date", value:"2018/12/26");
script_set_attribute(attribute:"patch_publication_date", value:"2018/12/26");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:powermonitor_1000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Rockwell");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Rockwell');
var asset = tenable_ot::assets::get(vendor:'Rockwell');
var vuln_cpes = {
"cpe:/o:rockwellautomation:powermonitor_1000_firmware" :
{"versionEndExcluding" : "4.019", "family" : "PowerMonitor1000"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:N/C:N/I:P/A:N
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
CHANGED
Confidentiality Impact
LOW
Integrity Impact
LOW
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
AI Score
Confidence
High
EPSS
Percentile
73.1%