8.1 High
CVSS3
Attack Vector
ADJACENT
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
NONE
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
6.7 Medium
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
20.4%
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that was listed in the OT:ICEFALL report. Ensure your OT deployments follow best practices including accurate inventory, separation of environments, and monitoring. This plugin will trigger on any device seen by Tenable.OT that matches a family or model listed in the OT:ICEFALL report.
Note: All findings need to be manually verified based on the advisory from the vendor, once released.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500655);
script_version("1.7");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");
script_cve_id("CVE-2022-30319", "CVE-2022-30320");
script_name(english:"Honeywell Saia Burgess PG5 PCD Authentication Bypass Using an Alternate Path or Channel (CVE-2022-30319, CVE-2022-30320)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset may be affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities
identify the insecure-by-design nature of OT devices and may not have a clear
remediation path. As such, Nessus is unable to test specifically for these
vulnerabilities but has identified the device to be one that was listed in the
OT:ICEFALL report. Ensure your OT deployments follow best practices including
accurate inventory, separation of environments, and monitoring. This plugin will
trigger on any device seen by Tenable.OT that matches a family or model listed
in the OT:ICEFALL report.
Note: All findings need to be manually verified based on the advisory from the vendor, once released.
This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
# https://www.cisa.gov/uscert/ncas/current-activity/2022/06/22/cisa-releases-security-advisories-related-oticefall-insecure
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?4901fbd6");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-207-03");
script_set_attribute(attribute:"see_also", value:"https://www.forescout.com/research-labs/ot-icefall/");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Honeywell recommends users with affected products and unsupported products take the following steps to protect
themselves:
- Apply product updates as available.
- Follow guidance in the product security manual to ensure isolation of network segments upon which automation
controllers reside.
- Ensure adequate security controls are in place between OT and IT network segments.
- Disable unnecessary accounts and services.
- Follow a least privilege approach and restrict system access to authorized personnel.
- Apply defense-in-depth strategies.
- Log and monitor network traffic for suspicious activity.");
script_set_cvss_base_vector("CVSS2#AV:A/AC:L/Au:N/C:C/I:C/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-30319");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2022/06/22");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/06/22");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/h:saia_burgess_controls:pcd_controllers");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Saia");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Saia');
var asset = tenable_ot::assets::get(vendor:'Saia');
var vuln_cpes = {
"cpe:/h:saia_burgess_controls:pcd_controllers" :
{"family" : "PCD"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Vendor | Product | Version | CPE |
---|---|---|---|
saia_burgess_controls | pcd_controllers | cpe:/h:saia_burgess_controls:pcd_controllers |
8.1 High
CVSS3
Attack Vector
ADJACENT
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
NONE
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
6.7 Medium
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
20.4%