CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:P/I:P/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
86.3%
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500328);
script_version("1.6");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/24");
script_cve_id("CVE-2018-7847");
script_name(english:"Schneider Electric Modicon Improper Authentication (CVE-2018-7847)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon
Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting
configuration settings of the controller over Modbus.
This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
# https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c0ded1b9");
# https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0742
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?f3265e28");
# https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-134-11
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?a432fe19");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-7847");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(284);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/05/22");
script_set_attribute(attribute:"patch_publication_date", value:"2019/05/22");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_quantum_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_premium_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:modicon_m580_series_firmware" :
{"versionEndExcluding" : "2.90", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m340_series_firmware" :
{"versionEndExcluding" : "3.10", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_quantum_firmware" :
{"family" : "QuantumUnity"},
"cpe:/o:schneider-electric:modicon_premium_firmware" :
{"family" : "Premium"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:P/I:P/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
86.3%