Lucene search

K
nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2020-7487.NASL
HistoryMar 01, 2023 - 12:00 a.m.

Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2020-7487)

2023-03-0100:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
9
schneider electric
modicon
data authenticity
cve-2020-7487
remote ot asset
tenable.ot

9.7 High

AI Score

Confidence

High

0.002 Low

EPSS

Percentile

60.7%

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500854);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/24");

  script_cve_id("CVE-2020-7487");

  script_name(english:"Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2020-7487)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-345: Insufficient Verification of Data Authenticity
vulnerability exists which could allow the attacker to execute
malicious code on the Modicon M218, M241, M251, and M258 controllers.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.se.com/ww/en/download/document/SEVD-2020-105-02");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-7487");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(345);

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/04/22");
  script_set_attribute(attribute:"patch_publication_date", value:"2020/04/22");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/03/01");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m218_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m241_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m251_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m258_series_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:modicon_m218_series_firmware" :
        {"family" : "ModiconM218"},
    "cpe:/o:schneider-electric:modicon_m241_series_firmware" :
        {"family" : "ModiconM241"},
    "cpe:/o:schneider-electric:modicon_m251_series_firmware" :
        {"family" : "ModiconM251"},
    "cpe:/o:schneider-electric:modicon_m258_series_firmware" :
        {"family" : "ModiconM258"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
schneider-electricmodicon_m218_series_firmwarecpe:/o:schneider-electric:modicon_m218_series_firmware
schneider-electricmodicon_m241_series_firmwarecpe:/o:schneider-electric:modicon_m241_series_firmware
schneider-electricmodicon_m251_series_firmwarecpe:/o:schneider-electric:modicon_m251_series_firmware
schneider-electricmodicon_m258_series_firmwarecpe:/o:schneider-electric:modicon_m258_series_firmware

9.7 High

AI Score

Confidence

High

0.002 Low

EPSS

Percentile

60.7%

Related for TENABLE_OT_SCHNEIDER_CVE-2020-7487.NASL