Lucene search

K
nessusThis script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2021-22713.NASL
HistoryJul 21, 2022 - 12:00 a.m.

Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22713)

2022-07-2100:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
16
schneider electric
powerlogic
ion
vulnerability
memory buffer

CVSS2

7.8

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

EPSS

0.001

Percentile

35.4%

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500671);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/10/17");

  script_cve_id("CVE-2021-22713");

  script_name(english:"Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22713)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-119:Improper restriction of operations within the bounds of a
memory buffer vulnerability exists in PowerLogic ION8650, ION8800,
ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security
notifcation for affected versions), which could cause the meter to
reboot.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.se.com/ww/en/download/document/SEVD-2021-068-03");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-22713");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(119);

  script_set_attribute(attribute:"vuln_publication_date", value:"2021/03/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2021/03/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/07/21");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:ion7650_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7300_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7550_firmware:376");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7550_firmware:416");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7650_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7700_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8300_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8600_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8650_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8800_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:powerlogic_ion8650_firmware" :
        {"versionEndExcluding" : "4.40.1", "family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion8800_firmware" :
        {"versionEndExcluding" : "372", "family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion7550_firmware:376" :
        {"versionEndExcluding" : "376", "family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion7650_firmware" :
        {"versionEndExcluding" : "376", "family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion7700_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion7300_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion8300_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion8400_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion8500_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion8600_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_ion7550_firmware:416" :
        {"versionEndExcluding" : "416", "family" : "ION"},
    "cpe:/o:schneider-electric:ion7650_firmware" :
        {"versionEndExcluding" : "416", "family" : "ION"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

CVSS2

7.8

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

EPSS

0.001

Percentile

35.4%

Related for TENABLE_OT_SCHNEIDER_CVE-2021-22713.NASL