Lucene search

K
nessusThis script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2016-2846.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Siemens SIMATIC S7-1200 Improper Privilege Management (CVE-2016-2846)

2022-02-0700:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
14
siemens
simatic s7-1200
vulnerability
improper privilege management
bypass user program
asset
remote
protection mechanism

CVSS2

6.4

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:P/A:N

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

AI Score

6.5

Confidence

High

EPSS

0.003

Percentile

68.1%

Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a user program block protection mechanism via unspecified vectors.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500238);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");

  script_cve_id("CVE-2016-2846");
  script_xref(name:"ICSA", value:"16-075-01");

  script_name(english:"Siemens SIMATIC S7-1200 Improper Privilege Management (CVE-2016-2846)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a user program block protection
mechanism via unspecified vectors.  

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  # http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c50c0565");
  script_set_attribute(attribute:"see_also", value:"https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-2846");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(254);

  script_set_attribute(attribute:"vuln_publication_date", value:"2016/03/16");
  script_set_attribute(attribute:"patch_publication_date", value:"2016/03/16");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7_cpu_1200_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7_cpu_1200_firmware" :
        {"versionEndIncluding" : "3.0.2", "family" : "S71200"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

CVSS2

6.4

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:P/A:N

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

AI Score

6.5

Confidence

High

EPSS

0.003

Percentile

68.1%