Lucene search

K
nessusThis script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2020-10037.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Siemens SICAM MMU, SICAM T, and SICAM SGU Out-of-Bounds Read (CVE-2020-10037)

2022-02-0700:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
26
siemens
sicam mmu
sicam t
sicam sgu
out-of-bounds read
cve-2020-10037
web server
memory access
firmware update
authentication
encryption
vpn
industrial security
cybersecurity

CVSS2

5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

AI Score

7.6

Confidence

High

EPSS

0.001

Percentile

48.0%

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device’s memory, possibly revealing confidential information.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500425);
  script_version("1.9");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");

  script_cve_id("CVE-2020-10037");
  script_xref(name:"ICSA", value:"20-196-03");

  script_name(english:"Siemens SICAM MMU, SICAM T, and SICAM SGU Out-of-Bounds Read (CVE-2020-10037)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions
< V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the
device's memory, possibly revealing confidential information.  

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-20-196-03");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens recommends applying updates, where available:

- SICAM MMU: Update to v2.05
- SICAM SGU: For RTU applications, upgrade the discontinued SICAM SGU devices to SICAM A8000 RTUs.
- SICAM T: Update to v2.18

Siemens has identified the following specific workarounds and mitigations that users can apply to reduce the risk:

- The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some
unnecessary functionality. The web authentication functionality reduces the risk of access to the deviceҀ™s web
application for executing administrative commands by unauthenticated users.
- Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by
the devices need to be protected on the network by other means, e.g., by VPN.
- The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption
and authentication between the user and the device, e.g., by VPN.
- Use a modern and up to date browser.

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the
environment according to the Siemens operational guidelines for Industrial Security and following the recommendations in
the product manuals.

For additional information, please refer to Siemens Security Advisory SSA-305120");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-10037");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(125);

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/07/14");
  script_set_attribute(attribute:"patch_publication_date", value:"2020/07/14");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:sicam_mmu_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:sicam_sgu_firmware:-");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:sicam_t_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:sicam_mmu_firmware" :
        {"versionEndExcluding" : "2.05", "family" : "Sicam"},
    "cpe:/o:siemens:sicam_sgu_firmware:-" :
        {"family" : "Sicam"},
    "cpe:/o:siemens:sicam_t_firmware" :
        {"versionEndExcluding" : "2.18", "family" : "Sicam"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

CVSS2

5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

AI Score

7.6

Confidence

High

EPSS

0.001

Percentile

48.0%

Related for TENABLE_OT_SIEMENS_CVE-2020-10037.NASL