Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2020-27339.NASL
HistorySep 26, 2023 - 12:00 a.m.

Siemens InsydeH2O Improper Input Validation (CVE-2020-27339)

2023-09-2600:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
8
siemens
insydeh2o
smm drivers
input validation
cve-2020-27339
firmware
os memory
tenable.ot
vulnerability
bios
ruggedcom ape
simatic devices
security scanner

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

6.7 Medium

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

12.8%

In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501693);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/09/27");

  script_cve_id("CVE-2020-27339");

  script_name(english:"Siemens InsydeH2O Improper Input Validation (CVE-2020-27339)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not
correctly validate the CommBuffer and CommBufferSize parameters,
allowing callers to corrupt either the firmware or the OS memory. The
fixed versions for this issue in the AhciBusDxe, IdeBusDxe,
NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are
05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1
through 5.5).

Insyde BIOS is typically used in RUGGEDCOM APE products 
and some SIMATIC devices. Please refer to the vendor advisory for a 
precise list of models concerned.

This plugin only works with Tenable.ot
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge/SA-2021001");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20220216-0005/");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-27339");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2021/06/16");
  script_set_attribute(attribute:"patch_publication_date", value:"2021/06/16");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/26");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:insyde:insydeh2o:5.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:insyde:insydeh2o:5.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:insyde:insydeh2o:5.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:insyde:insydeh2o:5.4");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:insyde:insydeh2o:5.3" :
        {"versionEndExcluding" : "5.35.25", "versionStartIncluding" : "5.3", "family" : "APE1808"},
    "cpe:/o:insyde:insydeh2o:5.2" :
        {"versionEndExcluding" : "5.26.25", "versionStartIncluding" : "5.2", "family" : "APE1808"},
    "cpe:/o:insyde:insydeh2o:5.1" :
        {"versionEndExcluding" : "5.16.25", "versionStartIncluding" : "5.1", "family" : "APE1808"},
    "cpe:/o:insyde:insydeh2o:5.4" :
        {"versionEndExcluding" : "5.43.25", "versionStartIncluding" : "5.4", "family" : "APE1808"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
insydeinsydeh2o5.1cpe:/o:insyde:insydeh2o:5.1
insydeinsydeh2o5.2cpe:/o:insyde:insydeh2o:5.2
insydeinsydeh2o5.3cpe:/o:insyde:insydeh2o:5.3
insydeinsydeh2o5.4cpe:/o:insyde:insydeh2o:5.4

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

6.7 Medium

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

12.8%

Related for TENABLE_OT_SIEMENS_CVE-2020-27339.NASL