Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2021-33625.NASL
HistorySep 26, 2023 - 12:00 a.m.

Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-33625)

2023-09-2600:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
4
siemens
insydeh2o
buffer overflow
vulnerability
bios
ruggedcom ape
simatic
tenable.ot
cve-2021-33625
security scanner

6.9 Medium

CVSS2

Attack Vector

LOCAL

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:M/Au:N/C:C/I:C/A:C

7.5 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

HIGH

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

5.1%

An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501705);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/09/27");

  script_cve_id("CVE-2021-33625");

  script_name(english:"Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-33625)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting
HddPassword. Software SMI services that use the Communicate() function
of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address
of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel
addresses.

Insyde BIOS is typically used in RUGGEDCOM APE products 
and some SIMATIC devices. Please refer to the vendor advisory for a 
precise list of models concerned.

This plugin only works with Tenable.ot
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge/SA-2022014");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20220222-0004/");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:M/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-33625");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(119);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/26");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.5");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/a:insyde:insydeh2o:5.1" :
        {"versionEndExcluding" : "5.16.23", "versionStartIncluding" : "5.1", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.2" :
        {"versionEndExcluding" : "5.26.23", "versionStartIncluding" : "5.2", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.3" :
        {"versionEndExcluding" : "5.35.23", "versionStartIncluding" : "5.3", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.4" :
        {"versionEndExcluding" : "5.43.22", "versionStartIncluding" : "5.4", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.5" :
        {"versionEndExcluding" : "5.51.22", "versionStartIncluding" : "5.5", "family" : "APE1808"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
insydeinsydeh2o5.1cpe:/a:insyde:insydeh2o:5.1
insydeinsydeh2o5.2cpe:/a:insyde:insydeh2o:5.2
insydeinsydeh2o5.3cpe:/a:insyde:insydeh2o:5.3
insydeinsydeh2o5.4cpe:/a:insyde:insydeh2o:5.4
insydeinsydeh2o5.5cpe:/a:insyde:insydeh2o:5.5

6.9 Medium

CVSS2

Attack Vector

LOCAL

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:M/Au:N/C:C/I:C/A:C

7.5 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

HIGH

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

5.1%

Related for TENABLE_OT_SIEMENS_CVE-2021-33625.NASL