Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2021-33627.NASL
HistorySep 26, 2023 - 12:00 a.m.

Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-33627)

2023-09-2600:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
3
siemens
insydeh2o
memory buffer restriction
fwblockservicesmm
ruggedcom ape
simatic
tenable.ot
vulnerability
efi_smm_communication_protocol
smram
mmio

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

8.2 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

20.6%

An issue was discovered in Insyde InsydeH2O 5.x, affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501728);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/09/27");

  script_cve_id("CVE-2021-33627");

  script_name(english:"Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-33627)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An issue was discovered in Insyde InsydeH2O 5.x, affecting
FwBlockServiceSmm. Software SMI services that use the Communicate()
function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether
the address of the buffer is valid, which allows use of SMRAM, MMIO,
or OS kernel addresses

Insyde BIOS is typically used in RUGGEDCOM APE products 
and some SIMATIC devices. Please refer to the vendor advisory for a 
precise list of models concerned.

This plugin only works with Tenable.ot
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge/SA-2022022");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20220222-0002/");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-33627");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(119);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/26");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.3");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/a:insyde:insydeh2o:5.0" :
        {"versionEndExcluding" : "5.08.29", "versionStartIncluding" : "5.0", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.1" :
        {"versionEndExcluding" : "5.16.29", "versionStartIncluding" : "5.1", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.2" :
        {"versionEndExcluding" : "5.26.29", "versionStartIncluding" : "5.2", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.3" :
        {"versionEndExcluding" : "5.35.29", "versionStartIncluding" : "5.3", "family" : "APE1808"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
insydeinsydeh2o5.0cpe:/a:insyde:insydeh2o:5.0
insydeinsydeh2o5.1cpe:/a:insyde:insydeh2o:5.1
insydeinsydeh2o5.2cpe:/a:insyde:insydeh2o:5.2
insydeinsydeh2o5.3cpe:/a:insyde:insydeh2o:5.3

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

8.2 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

20.6%

Related for TENABLE_OT_SIEMENS_CVE-2021-33627.NASL