Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2021-41837.NASL
HistorySep 26, 2023 - 12:00 a.m.

Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-41837)

2023-09-2600:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
7
siemens
insydeh2o
memory buffer
bounds issue
ruggedcom ape
simatic
tenable.ot
untrusted pointer dereference
smm.

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

8.2 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

5.1%

An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501727);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/09/27");

  script_cve_id("CVE-2021-41837");

  script_name(english:"Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-41837)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in
Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that
causes SMM memory corruption, an attacker may be able to write fixed
or predictable data to SMRAM. Exploiting this issue could lead to
escalating privileges to SMM.

Insyde BIOS is typically used in RUGGEDCOM APE products 
and some SIMATIC devices. Please refer to the vendor advisory for a 
precise list of models concerned.

This plugin only works with Tenable.ot
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge");
  script_set_attribute(attribute:"see_also", value:"https://www.insyde.com/security-pledge/SA-2022024");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20220222-0003/");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-41837");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(119);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/02/03");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/26");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:insyde:insydeh2o:5.5");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/a:insyde:insydeh2o:5.0" :
        {"versionEndExcluding" : "5.08.41", "versionStartIncluding" : "5.0", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.1" :
        {"versionEndExcluding" : "5.16.41", "versionStartIncluding" : "5.1", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.2" :
        {"versionEndExcluding" : "5.26.41", "versionStartIncluding" : "5.2", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.3" :
        {"versionEndExcluding" : "5.35.41", "versionStartIncluding" : "5.3", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.4" :
        {"versionEndExcluding" : "5.43.41", "versionStartIncluding" : "5.4", "family" : "APE1808"},
    "cpe:/a:insyde:insydeh2o:5.5" :
        {"versionEndExcluding" : "5.51.41", "versionStartIncluding" : "5.5", "family" : "APE1808"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
insydeinsydeh2o5.0cpe:/a:insyde:insydeh2o:5.0
insydeinsydeh2o5.1cpe:/a:insyde:insydeh2o:5.1
insydeinsydeh2o5.2cpe:/a:insyde:insydeh2o:5.2
insydeinsydeh2o5.3cpe:/a:insyde:insydeh2o:5.3
insydeinsydeh2o5.4cpe:/a:insyde:insydeh2o:5.4
insydeinsydeh2o5.5cpe:/a:insyde:insydeh2o:5.5

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

8.2 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

5.1%

Related for TENABLE_OT_SIEMENS_CVE-2021-41837.NASL