Siemens SCALANCE XCM332 Concurrent Execution Using Shared Resource with Improper Synchronization (CVE-2022-1729)

2023-05-0200:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
12
siemens
scalance xcm332
concurrent execution
shared resource
improper synchronization
vulnerability
linux kernel
tenable.ot

6.9 Medium

AI Score

Confidence

High

0.0004 Low

EPSS

Percentile

16.0%

A race condition was found the Linux kernel in perf_event_open() which can be exploited by an unprivileged user to gain root privileges. The bug allows to build several exploit primitives such as kernel address information leak, arbitrary execution, etc.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501081);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/04/22");

  script_cve_id("CVE-2022-1729");

  script_name(english:"Siemens SCALANCE XCM332 Concurrent Execution Using Shared Resource with Improper Synchronization (CVE-2022-1729)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A race condition was found the Linux kernel in perf_event_open() which
can be exploited by an unprivileged user to gain root privileges. The
bug allows to build several exploit primitives such as kernel address
information leak, arbitrary execution, etc.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-09
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?4af41997");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-558014.html");
  script_set_attribute(attribute:"see_also", value:"https://www.openwall.com/lists/oss-security/2022/05/20/2");
  # https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=3ac6487e584a1eb54071dbe1212e05b884136704
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?79efc46a");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20230214-0006/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-09");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has released an update for the SCALANCE XCM332 and recommends updating to the latest version: 

- SCALANCE XCM332 (6GK5332-0GA01-2AC2): Update to V2.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemensรขย€ย™
operational guidelines for industrial security and following the recommendations in the product manuals. Additional
information on Industrial Security by Siemens can be found at the Siemens Industrial Security web page.

For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the Siemens
ProductCERT.

For more information see the associated Siemens security advisory SSA-558014 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:H/Au:S/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-1729");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(362);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/09/01");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/09/01");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/05/02");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_xcm332_firmware" :
        {"versionEndExcluding" : "2.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);