CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
AI Score
Confidence
High
EPSS
Percentile
59.4%
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501664);
script_version("1.5");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");
script_cve_id("CVE-2022-36362");
script_xref(name:"ICSA", value:"22-286-13");
script_name(english:"Siemens LOGO! 8 BM Devices Improper Input Validation (CVE-2022-36362)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS
variants) (All versions). Affected devices do not conduct certain
validations when interacting with them. This could allow an
unauthenticated remote attacker to manipulate the devices IP address,
which means the device would not be reachable and could only be
recovered by power cycling the device.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-286-13");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens is preparing updates and recommends specific countermeasures for products where updates are not yet available:
- Only for versions prior to V8.3: Restrict access to port 10005/TCP to only trusted IP addresses.
- Only for versions including and since V8.3: Restrict access to port 8443/TCP to only trusted IP addresses.
- Restrict access to port 135/TCP to trusted IP addresses only.
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the
environment according to Siemens' operational guidelines for industrial security and following the recommendations in
the product manuals.
Siemens has provided additional information on industrial security.
For more information, see the associated Siemens Security Advisory SSA-955858 in HTML or CSAF formats.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-36362");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2022/10/11");
script_set_attribute(attribute:"patch_publication_date", value:"2022/10/11");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/21");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:logo%218_bm_fs-05_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:logo%21_8_bm_firmware");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:logo%21_8_bm_firmware" :
{"family" : "LOGO!BM"},
"cpe:/o:siemens:logo%218_bm_fs-05_firmware" :
{"family" : "LOGO!BM"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
AI Score
Confidence
High
EPSS
Percentile
59.4%