Lucene search

K
nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2022-40178.NASL
HistoryJan 25, 2023 - 12:00 a.m.

Siemens Desigo PXM Devices Improper Neutralization of Input During Web Page Generation (CVE-2022-40178)

2023-01-2500:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
16
siemens desigo pxm
vulnerability
input neutralization
web application
remote attack
javascript code
tenable.ot

AI Score

6.2

Confidence

High

EPSS

0.001

Percentile

29.2%

A vulnerability has been identified in Desigo PXM30-1 (All versions < V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41), Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All versions < V02.20.126.11-41), Desigo PXM50-1 (All versions < V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41), PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All versions < V02.20.126.11-41), PXG3.W200-1 (All versions < V02.20.126.11-37), PXG3.W200-2 (All versions < V02.20.126.11-41).
Improper Neutralization of Input During Web Page Generation exists in the Import Files functionality of the Operation web application, due to the missing validation of the titles of files included in the input package. By uploading a specifically crafted graphics package, a remote low-privileged attacker can execute arbitrary JavaScript code.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500774);
  script_version("1.6");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/04/11");

  script_cve_id("CVE-2022-40178");

  script_name(english:"Siemens Desigo PXM Devices Improper Neutralization of Input During Web Page Generation (CVE-2022-40178)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in Desigo PXM30-1 (All versions <
V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41),
Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All
versions < V02.20.126.11-41), Desigo PXM50-1 (All versions <
V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41),
PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All
versions < V02.20.126.11-41), PXG3.W200-1 (All versions <
V02.20.126.11-37), PXG3.W200-2 (All versions < V02.20.126.11-41).
Improper Neutralization of Input During Web Page Generation exists in
the Import Files functionality of the Operation web application,
due to the missing validation of the titles of files included in the
input package. By uploading a specifically crafted graphics package, a
remote low-privileged attacker can execute arbitrary JavaScript code.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-360783.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-286-06");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has released updates for the affected products and recommends users update to the latest versions:

- Desigo PXM30-1: Update to V02.20.126.11-41 or later
- Desigo PXM30.E: Update to V02.20.126.11-41 or later
- Desigo PXM40-1: Update to V02.20.126.11-41 or later
- Desigo PXM40.E: Update to V02.20.126.11-41 or later
- Desigo PXM50-1: Update to V02.20.126.11-41 or later
- Desigo PXM50.E: Update to V02.20.126.11-41 or later
- PXG3.W100-1: Update to V02.20.126.11-37 or later
- PXG3.W100-2: Update to V02.20.126.11-41 or later
- PXG3.W200-1: Update to V02.20.126.11-37 or later
- PXG3.W200-2: Update to V02.20.126.11-41 or later

 As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to SiemensҀ™
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information, see the associated Siemens Security Advisory in HTML or CSAF formats.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:S/C:P/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-40178");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(79);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/10/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/10/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/01/25");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm30-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm30.e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm40-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm40.e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm50-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm50.e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w100-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w100-2_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w200-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w200-2_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:desigo_pxm30-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm30.e_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm40-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm40.e_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm50-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm50.e_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w100-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-37", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w100-2_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w200-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-37", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w200-2_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

AI Score

6.2

Confidence

High

EPSS

0.001

Percentile

29.2%

Related for TENABLE_OT_SIEMENS_CVE-2022-40178.NASL