CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
NONE
Scope
CHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
AI Score
Confidence
High
EPSS
Percentile
52.4%
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The software-upgrade Url parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501637);
script_version("1.7");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");
script_cve_id("CVE-2023-36750");
script_xref(name:"ICSA", value:"23-194-01");
script_name(english:"Siemens RUGGEDCOM ROX Improper Neutralization of Special Elements Used in a Command (CVE-2023-36750)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All
versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0),
RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500
(All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions <
V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX
RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions <
V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX
RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions <
V2.16.0). The software-upgrade Url parameter in the web interface of
affected devices is vulnerable to command injection due to missing
server side input sanitation. This could allow an authenticated
privileged remote attacker to execute arbitrary code with root
privileges.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-194-01");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
âSiemens recommends users update the product to the following versions:
- âUpdate to V2.16.0 or later version
âAs a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the
environment according to Siemens' operational guidelines for Industrial Security, and to follow the recommendations in
the product manuals. Additional information on Industrial Security by Siemens can be found at:
https://www.siemens.com/industrialsecurity
âFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens
ProductCERT: https://www.siemens.com/cert/advisories
âAs a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
âAdditional information on industrial security by Siemens can be found on the Siemens industrial security webpage.
âFor more information see the associated Siemens security advisory SSA-146325 in HTML and CSAF.
â");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:M/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-36750");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(77);
script_set_attribute(attribute:"vuln_publication_date", value:"2023/07/11");
script_set_attribute(attribute:"patch_publication_date", value:"2023/07/11");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/14");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"current");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
NONE
Scope
CHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
AI Score
Confidence
High
EPSS
Percentile
52.4%