According to its model number and software version, the remote host is a Xerox WorkCentre device that is reportedly prone to a code injection issue that could allow execution of arbitrary code on the remote host.
#
# (C) Tenable Network Security, Inc.
#
include("compat.inc");
if (description)
{
script_id(22498);
script_version("1.16");
script_cvs_date("Date: 2018/11/15 20:50:24");
script_cve_id("CVE-2006-5290");
script_bugtraq_id(20334);
script_name(english:"Xerox WorkCentre WebUI Arbitrary Command Execution (XRX06-005)");
script_summary(english:"Checks Net Controller Software version of Xerox WorkCentre devices");
script_set_attribute(
attribute:"synopsis",
value:
"The remote multi-function device is prone to a code injection
vulnerability."
);
script_set_attribute(
attribute:"description",
value:
"According to its model number and software version, the remote host
is a Xerox WorkCentre device that is reportedly prone to a code
injection issue that could allow execution of arbitrary code on the
remote host."
);
script_set_attribute(attribute:"see_also", value:"https://www.xerox.com/downloads/usa/en/c/cert_XRX06_005.pdf");
script_set_attribute(attribute:"solution", value:
"Apply the P29 patch as described in the Xerox security bulletins.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2006/10/03");
script_set_attribute(attribute:"patch_publication_date", value:"2006/10/03");
script_set_attribute(attribute:"plugin_publication_date", value:"2006/10/05");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/h:xerox:workcentre");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Misc.");
script_copyright(english:"This script is Copyright (C) 2006-2018 Tenable Network Security, Inc.");
script_dependencies("xerox_workcentre_detect.nasl");
script_require_keys("www/xerox_workcentre");
exit(0);
}
include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");
# This function returns TRUE if the version string ver lies in
# the range [low, high].
function ver_inrange(ver, low, high)
{
local_var ver_parts, low_parts, high_parts, i, p, low_p, high_p;
if (isnull(ver) || isnull(low) || isnull(high)) return FALSE;
# Split levels into parts.
ver_parts = split(ver, sep:".", keep:0);
low_parts = split(low, sep:".", keep:0);
high_parts = split(high, sep:".", keep:0);
# Compare each part.
i = 0;
while (ver_parts[i] != NULL)
{
p = int(ver_parts[i]);
low_p = int(low_parts[i]);
if (low_p == NULL) low_p = 0;
high_p = int(high_parts[i]);
if (high_p == NULL) high_p = 0;
if (p > low_p && p < high_p) return TRUE;
if (p < low_p || p > high_p) return FALSE;
++i;
}
return TRUE;
}
# Check whether the device is vulnerable.
if (get_kb_item("www/xerox_workcentre"))
{
model = get_kb_item_or_exit("www/xerox_workcentre/model");
ess = get_kb_item_or_exit("www/xerox_workcentre/ess");
# No need to check further if ESS has ".P29" since that
# indicates the patch has already been applied.
if (ess && ess =~ "\.P29") audit(AUDIT_HOST_NOT, "affected");
# Test model number and software version against those in Xerox's security bulletin.
if (
# nb: models 232/238/245/255/265/275 with ESS in [040.010.0930, 040.010.2280).
(model =~ "^2(3[28]|[4-7]5)" || model =~ "Pro 2(3[28]|[4-7]5)") &&
ver_inrange(ver:ess, low:"040.010.0930", high:"040.010.2279")
)
security_hole(0);
exit(0);
}