CVSS2
Attack Vector
LOCAL
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:L/AC:L/Au:N/C:P/I:N/A:N
CVSS3
Attack Vector
PHYSICAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
NONE
Availability Impact
NONE
CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
AI Score
Confidence
High
EPSS
Percentile
21.9%
A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app’s directory. Siemens provides mitigations to resolve the security issue.
Vendor | Product | Version | CPE |
---|---|---|---|
siemens | simatic_wincc_oa_operator | - | cpe:2.3:a:siemens:simatic_wincc_oa_operator:-:*:*:*:*:iphone_os:*:* |
CVSS2
Attack Vector
LOCAL
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:L/AC:L/Au:N/C:P/I:N/A:N
CVSS3
Attack Vector
PHYSICAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
NONE
Availability Impact
NONE
CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
AI Score
Confidence
High
EPSS
Percentile
21.9%