CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:N/C:N/I:P/A:N
AI Score
Confidence
High
EPSS
Percentile
59.9%
Siemens SIMATIC S7-1200 Programmable Logic Controller (PLC) is
prone to a cross-site scripting (XSS) vulnerability because it fails to properly sanitize
user-supplied input.
# Copyright (C) 2012 Greenbone Networks GmbH
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-or-later
#
# This program is free software; you can redistribute it and/or
# modify it under the terms of the GNU General Public License
# as published by the Free Software Foundation; either version 2
# of the License, or (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software
# Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA.
CPE = "cpe:/a:siemens:simatic_s7_1200";
if (description)
{
script_oid("1.3.6.1.4.1.25623.1.0.103584");
script_version("2022-04-27T04:20:28+0000");
script_tag(name:"cvss_base", value:"4.3");
script_tag(name:"cvss_base_vector", value:"AV:N/AC:M/Au:N/C:N/I:P/A:N");
script_cve_id("CVE-2012-3040");
script_name("Siemens SIMATIC S7-1200 PLC 'web server' Component XSS Vulnerability (SSA-279823)");
script_xref(name:"URL", value:"http://www.securityfocus.com/bid/55841");
script_xref(name:"URL", value:"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf");
script_tag(name:"last_modification", value:"2022-04-27 04:20:28 +0000 (Wed, 27 Apr 2022)");
script_tag(name:"creation_date", value:"2012-10-10 12:27:02 +0200 (Wed, 10 Oct 2012)");
script_category(ACT_GATHER_INFO);
script_family("Web application abuses");
script_copyright("Copyright (C) 2012 Greenbone Networks GmbH");
script_dependencies("gb_siemens_simatic_s7_consolidation.nasl");
script_mandatory_keys("siemens/simatic_s7/detected");
script_tag(name:"summary", value:"Siemens SIMATIC S7-1200 Programmable Logic Controller (PLC) is
prone to a cross-site scripting (XSS) vulnerability because it fails to properly sanitize
user-supplied input.");
script_tag(name:"vuldetect", value:"Checks if a vulnerable version is present on the target host.");
script_tag(name:"impact", value:"An attacker may leverage this issue to execute arbitrary script
code in the browser of an unsuspecting user in the context of the affected site. This can allow
the attacker to steal cookie-based authentication credentials and launch other attacks.");
script_tag(name:"solution", value:"Updates are available. Please see the references for more
information.");
script_tag(name:"qod_type", value:"remote_banner");
script_tag(name:"solution_type", value:"VendorFix");
exit(0);
}
include("host_details.inc");
include("version_func.inc");
if(!version = get_app_version(cpe: CPE, nofork: TRUE))
exit(0);
if(version_is_less_equal(version: version, test_version: "3.0.1")) {
report = report_fixed_ver(installed_version: version, fixed_version: "3.0.2");
security_message(port: 0, data: report);
exit(0);
}
exit(99);