HistoryMar 26, 2019 - 5:29 p.m.

Out-of-bounds

2019-03-2617:29:00
PRIOn knowledge base
www.prio-n.com
1

7 High

AI Score

Confidence

Low

0.001 Low

EPSS

Percentile

23.5%

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the โ€œTotal Record Sizeโ€ field. By sending a datagram to the service over Port 4444/UDP with the โ€œRecord Data Sizeโ€ field modified to a specifically oversized value, the service will calculate an undersized value for the โ€œTotal Record Sizeโ€ that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

7 High

AI Score

Confidence

Low

0.001 Low

EPSS

Percentile

23.5%