FANUC ROBOGUIDE-HandlingPRO Versions 9 Rev.ZD and prior is vulnerable to a path traversal, which could allow an attacker to remotely read files on the system running the affected...
7.5CVSS
7.3AI Score
0.001EPSS
The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory...
6.1CVSS
6.2AI Score
0.001EPSS
The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege...
7CVSS
7AI Score
0.0004EPSS
The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference...
6.1CVSS
5.5AI Score
0.001EPSS
The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access...
6.1CVSS
6.3AI Score
0.001EPSS
The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege...
6CVSS
5.8AI Score
0.0004EPSS
The FANUC R-30iA and R-30iB series controllers are vulnerable to integer coercion errors, which cause the device to crash. A restart is...
7.5CVSS
7.5AI Score
0.001EPSS
The FANUC R-30iA and R-30iB series controllers are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. INIT START/restore from backup...
7.4CVSS
7.6AI Score
0.001EPSS
A denial-of-service vulnerability in the Fanuc i Series CNC (0i-MD and 0i Mate-MD) could allow an unauthenticated, remote attacker to cause an affected CNC to become inaccessible to other...
5.3CVSS
5.3AI Score
0.011EPSS
GE Fanuc iFIX 5.0 and earlier relies on client-side authentication involving a weakly encrypted local password file, which allows remote attackers to bypass intended access restrictions and start privileged server login sessions by recovering a password or by using a modified program...
7.2AI Score
0.011EPSS
Heap-based buffer overflow in w32rtr.exe in GE Fanuc CIMPLICITY HMI SCADA system 7.0 before 7.0 SIM 9, and earlier versions before 6.1 SP6 Hot fix - 010708_162517_6106, allow remote attackers to execute arbitrary code via unknown...
8AI Score
0.303EPSS
Unrestricted file upload vulnerability in GE Fanuc Proficy Real-Time Information Portal 2.6 and earlier allows remote attackers to execute arbitrary code by uploading a file with an executable extension to the main virtual...
7.5AI Score