Lucene search

K
cveSiemensCVE-2024-26276
HistoryApr 09, 2024 - 9:15 a.m.

CVE-2024-26276

2024-04-0909:15:24
CWE-770
siemens
web.nvd.nist.gov
35
vulnerability
parasolid
stack exhaustion
denial of service
x_t file

CVSS3

3.3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

LOW

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L

CVSS4

4.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

PASSIVE

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/SC:N/VI:N/SI:N/VA:L/SA:N

AI Score

3.9

Confidence

High

EPSS

0

Percentile

9.0%

A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.

CNA Affected

[
  {
    "vendor": "Siemens",
    "product": "JT2Go",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V2312.0004",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V35.1",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V35.1.254",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V36.0",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V36.0.207",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V36.1",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V36.1.147",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Teamcenter Visualization V14.2",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V14.2.0.12",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Teamcenter Visualization V14.3",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V14.3.0.9",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Teamcenter Visualization V2312",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V2312.0004",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  }
]

CVSS3

3.3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

LOW

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L

CVSS4

4.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

PASSIVE

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/SC:N/VI:N/SI:N/VA:L/SA:N

AI Score

3.9

Confidence

High

EPSS

0

Percentile

9.0%

Related for CVE-2024-26276