CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS4
Attack Vector
LOCAL
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
PASSIVE
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/SC:N/VI:H/SI:N/VA:H/SA:N
AI Score
Confidence
High
EPSS
Percentile
9.0%
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition or execute code within the context of the current process.
The following Siemens products, are affected:
The affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-26275 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-26275.
A base score of 7.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)).
The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial-of-service condition.
CVE-2024-26276 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).
A CVSS v4 score has also been calculated for CVE-2024-26276.
A base score of 4.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N)).
The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial-of-service condition.
CVE-2024-26277 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).
A CVSS v4 score has also been calculated for CVE-2024-26277.
A base score of 4.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N)).
Siemens reported these vulnerabilities to CISA.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-771940 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-26275
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-26275
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-26276
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-26276
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-26277
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-26277
cert-portal.siemens.com/productcert/csaf/ssa-771940.json
cert-portal.siemens.com/productcert/html/ssa-771940.html
cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-08
cwe.mitre.org/data/definitions/125.html
cwe.mitre.org/data/definitions/476.html
cwe.mitre.org/data/definitions/770.html
github.com/cisagov/CSAF
new.siemens.com/global/en/products/services/cert.html#SecurityPublications
plm.sw.siemens.com/en-US/plm-components/jt/jt2go/
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
support.sw.siemens.com/
support.sw.siemens.com/
twitter.com/CISAgov
twitter.com/intent/tweet?text=Siemens%20Teamcenter%20Visualization%20and%20JT2Go+https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-08
us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/onedrive.aspx?ga=1&id=%2Fpersonal%2Fgrayson%5Fgaylor%5Fassociates%5Fcisa%5Fdhs%5Fgov1%2FDocuments%2FNew%20Publishing%20%2D%20Grayson%20%26%20Bryan%2FJune%202024%2FJune%2013%2FVU%23391335%20%2D%20Siemens%20Teamcenter%20Visualization%20and%20JT2Go%20%28SSA%2D771940%29%20%2D%20Notice%20%28Draft%29%2Ehtml&parent=%2Fpersonal%2Fgrayson%5Fgaylor%5Fassociates%5Fcisa%5Fdhs%5Fgov1%2FDocuments%2FNew%20Publishing%20%2D%20Grayson%20%26%20Bryan%2FJune%202024%2FJune%2013
www.cisa.gov/resources-tools/resources/ics-recommended-practices
www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
www.cisa.gov/topics/industrial-control-systems
www.cisa.gov/topics/industrial-control-systems
www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
www.cisa.gov/uscert/ncas/tips/ST04-014
www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-08&title=Siemens%20Teamcenter%20Visualization%20and%20JT2Go
www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-08
www.oig.dhs.gov/
www.siemens.com/cert/operational-guidelines-industrial-security
www.siemens.com/industrialsecurity
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Siemens%20Teamcenter%20Visualization%20and%20JT2Go&body=www.cisa.gov/news-events/ics-advisories/icsa-24-165-08
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS4
Attack Vector
LOCAL
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
PASSIVE
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/SC:N/VI:H/SI:N/VA:H/SA:N
AI Score
Confidence
High
EPSS
Percentile
9.0%